Description
P5L is suitable for use in all establishments, including national institutions and institutions directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.PRODUCT PERFORMANCE AND ITS STRUCTUREThe descaling device is composed of electrical circuits, water channels and ultrasonic emitter.USAGEUltrasonic descaling device for removing tartar and other surface deposits teeth. The tip of the device produces ultrasonic vibrations that clean the teeth, the total removal of residues being achieved with the help of constant rinsing with water. TECHNICAL SPECIFICATIONS Technical performance specifications Power supply: 100-240 V~ 50/60 Hz 0.7 A- 0.4 A Equipment operating values: 30 V 12A8 Power supply unit fuse: 250V/T 1.6AL Useful power: 3W to 20WD Main tip oscillation deviation: ≤200µm Tip vibration frequency: 28kHz±3kHz Output deviation force: ˂2N Water pressure: 0.1MPa~0.5MPa; (1 bar~5 bar)Equipment weight: 0.55 kgPower unit weight: 0.34 kgOperation mode: continuous operationType of protection against overcharging (electric shock): Class IIClassification 93/42/EEC: Class IIDegree of protection against electric shock: BDegree of protection against forced water intake: Ordinary equipment, degree of protection against water (used on the foot pedal): IPX1Degree of safety in use in the presence of a flammable anesthetic; Mixture with air or oxygen or sodium oxide The equipment is not suitable for use in the presence of a flammable anesthetic mixed with air or with oxygen or sodium oxide WORKING ENVIRONMENTAL CONDITIONS: Ambient temperature: +10 ˚C + 40 ˚C Ambient humidity: 0 to 80% Atmospheric pressure: 700hPa to 1060hPa HOW TO USE Open packaging, make sure all parts and accessories listed on the packing slip are present. Take out the main unit from the box and place it on a stable plane. Turn the water valve to the maximum open position according to the symbol as shown in point 9.2.1 Insert the male plug of the foot switch into the appropriate place. Connect one end of the water hose to the water supply, lock the water pipe tightly with the lock nut, and connect the other end to a pure water source. Connect the handpiece with the cable (Illustration 7-3, 7-4, 7-5, 7-6), choose a graduated tip you need and screw it into the handpiece tightly with the torque wrench (Illustration 7-8). Turn off the central unit, then insert the power plug into a power source. Turn on the power button, and turn on the machine. Vibration intensity: adjust the vibration according to the requirements. Generally adjust to 3 or 4 degrees, but also adjust the vibration intensity according to the patient's sensitivity and tartar hardness at any time during the clinical treatment. Water volume adjustment: press the foot button and the tip vibrates, then turn on the water control button to form a fine spray to cool the handpiece and clean the teeth. Generally hold the handpiece in the posture of holding a pen in your hand. In clinical grading, do not use the tip vertically the tip in contact with the teeth, so as not to damage the teeth or the tip. The normal frequency is extremely high. In accordance with the normal state of graduated peaks, a light touch and some back and forth motion will remove tartar without heating. Long-term overwork and slow down are prohibited. After the operation is completed, keep the machines working for 20-30 seconds, under the condition of water supply to clean the handpiece and tips. Disassemble the tip, sterilize the handpiece, tips, and torque wrench. Note: Please do not remove the handpiece and tips when the foot switch is pressed, and the machine vibrates with ultrasound. Wholesale product available on the B2B marketplace, Supreva Market For Business, at wholesale prices directly from the distributor.